LattisSupport(tm)
Install
Product Specification
Basic Install(tm)
Designed for Ethernet and Token Ring local area networks (LANs) of moderate
size and complexity, Basic Install includes the following value-added
services:
* Site survey. SynOpakes a thorough technical assessment of
your entire premises so that all operational and environmental
requirements are met prior to installation. This is accomplished
via telephone or mail survey.
* Cable plant qualification. Your existing structured cabling system
is inspected and validated to ensure full support for 10BASE-T
Ethernet and Token Ring.
* Review and validate existing network design. SynOptics reviews your
existing network design, while validating the technical requirements
of your proposed plan.
* Equipment is unpacked and inspected. Every SynOptics product
received at your site is carefully unpacked and examined before the
installation proceeds.
* Installation of intelligent hubs. At a single site, any combination
of 10 System 2000(tm) or System 3000(tm) intelligent hubs are mounted in
customer-provided standard EIA equipment racks, on shelves or in a
table-top arrangement.
* Installation and configuration of intelligent hub modules.
LattisNet(R) city, local bridge and network management modules
for Ethernet and Token Ring are installed and configured in
intelligent hubs.
* Installation of transceivers and media filters. LattisNet
transceivers and media filters are installed at each station. Patch
cables are also installed to link end stations with wall jacks.
* Download and configure network management software. LattisNet
Manager(tm) for DOS and its associated agents are downloaded and
configured at your central network managet console.
* Attach and label all connections. Every connection is tagged and
all cables are attached to the appropriate intelligent hub modules
and patch panels.
* Document configurations and serial numbers. SynOptics provides
as-built documentation identifying locations, configurations, model
numbers and serial numbers of all LattisNet products. Warranty
documentation is also completed.
* Perform functional testing. SynOptics runs your newly-installed
network through a cycle of tests to ensure intelligent hub and
module operations and configuration integrity of network management
modules. All operational testing is fully documented.
Before implementing Basic Install, you are asked to provide SynOptics with the
following:
* A designated point-of-contact for the Basic Install project.
* Facility blueprints.
* Main and intermediate distribution frame rack and wiring
configurations.
* Network design drawings.
* Network bill of materials.
* Corporate premises wiring standard (if applicable).
* Site availability schedule.
If you do not provide these materials in a timely manner, or approve
variations, SynOptics will use its best effort to complete installation
services. SynOptics will not incur any liability for performance when the
required information is not forthcoming from you.
Premier Install(tm)
Premier Install includes everything in the Basic Install product, plus a
variety of other value-added services for large, complex networks spanning
mulle geographic locations:
* Timeframe. The timeframe for installation is quoted on an
individual basis and includes any number of System 2000 and
System 3000 intelligent hubs at multiple locations.
* Complete project management. SynOptics oversees your enterprise
network installation and handles all aspects of project management -
hiring subcontractors, supervising structured cabling installations,
coordinating equipment deliveries, and overseeing all aspects of
network implementation.
* Cable plant qualification. All structured cabling is inspected and
validated to support the high-performance Fiber Distributed Data
Interface (FDDI) as well as 10BASE-T Ethernet and Token Ring.
* Installation and configuration of FDDI networks. In addition to
Ethernet and Token Ring, SynOptics installs all FDDI concentrators,
connectivity modules and network management modules.
* Installation and configuration of remote internetworking and
terminal server modules. LattisNet remote bridges, remote routers
and terminal servers for Ethernet and Token Ring - as well as their
associated software - are installed in intelligent hubs and
configured for performance across your wide area network (WAN).
Cables from leased- line modems are connected to appropriate router
serial ports.
* Installation and configuration of the Network Control Engine(tm)
(NCE(tm)). LattisNet NCEs are installed and configured in intelligent
hubs at key strategic locations throughout your enterprise k.
* Download and configure the Optivity(tm) network management system.
SynOptics downloads and configures the UNIX-based Optivity network
management system and its associated agents at your central network
management console.
* Download and cigure LattisWare(tm) and NetMetrix(tm). LattisWare
management productivity tools and NetMetrix diagnostic software are
downloaded and configured at your central network management
console.
* Perform functional testing. SynOptics conducts end-toAN
testing through Telnet sessions between all routers and ensures the
configuration integrity of your network management console.
Before implementing Premier Install, you are asked to provide SynOptics
with the following:
* A designated point-of-contact.
* Facility blueprints.
* Site MDF and IDF rack and wiring configurations.
* Network design drawings.
* Network bill of materials.
* Corporate premises wiring standard, (if applicable).
* Site availability schedule.
* Required work permits.
* Access to electrical power sources required for network equipment.
* A secure, lockable area for storage of materials and tools.
If you do not provide these materials in a timely manner, or approve
variations, SynOptics will use its best effort to complete installation
services. SynOptics will not incur any liability for performance when the
required information is not forthcoming from you.
Basic Install and Premier
Install Terms and Conditions
Travel. Travel to sites within 50 miles of a SynOptics area office is
provided at no additional charge. Travel expenses for sites beyond 50 miles
will be charged according to the distance between the site and the closest
SynOptics supporting office. Premises wiring qualification. Only one cable
type per facility is included. Additional cable testing is available on a
time-and-materials basis.
Change orders. All change orders must be submitted in writing and authorized
by your designated project contact and approved by the SynOptics project
manager.
Third-party equipment. You are responsible for purchasing all third-party
equipment required for the installation.
Price. All prices quoted exclude sales tax, use and excise taxes, and customs
duties and shipping charges. These are your responsibility and will be added
and identified on each invoice sent to you.
Hours. LattisSupport Install prices are based on the standard work hours of
8 a.m. to 5 p.m., Monday through Friday. Other hours or shifts will require
price changes.
Patch cables. All patching and cross-connects are included for modular (i.e.,
RJ-45 to RJ-45) cables only. The punch down of cables onto connecting blocks
(e.g., 110s, 66s, etc.) requires price modifications.
Billing. SynOptics will issue a single invoice upon completion and customer
acceptance of a Basic Install project. The progress payment schedule required
for Premier Install includes 25 percent upon agreement, 25 percent upon
on-site project commencement and 50 percent upon project completion and
customer acceptance.
Project management. SynOptics project managers are responsible for the
scheduling, resource coordination, and overall implementation of the network.
System design is excluded.
Modifications to terms and conditions. Changes to the preceding terms and
conditions require custom-quoted proposals based on SynOptics' current
time-and-materials rate.
Customer acknowledges that (1) Customer's representative signing below is
authorized to do so on behalf of Customer and (2) Customer has read and
accepts the terms of service listed in this Product Specification.
AGREED: Customer Name Customer signature Date System 2000, System 3000, NCE,
Network Control Engine, Basic Install, Premier Install, Optivity, LattisWare,
and LattisSupport are trademarks and SynOptics Communications and LattisNet
are registered trademarks of SynOptics Communications, Inc. All other brand
and product names are trademarks or registered trademarks of their respective